[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fgKUFe78QQ3cuj0ZnpxGb6yk1aAxh1Ln-pcPWgEL0XtI":3,"g5a-family:siemens\u002Fsimatic_wincc_runtime":126,"g5a-ex:siemens\u002Fsimatic_wincc_runtime@*":139},{"success":4,"data":5},true,{"product":6,"versions":28,"topVulnerabilitiesByEpss":34,"kevVulnerabilities":98,"seoMetadata":104,"meta":123},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":27},"siemens","simatic_wincc_runtime",5,13,0,"2022-11-08",[14,18,20,22,25],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},"13",2,false,{"version":19,"cve_count":16,"kev_count":11,"has_kev":17},"14",{"version":21,"cve_count":11,"kev_count":11,"has_kev":17},"14.0",{"version":23,"cve_count":24,"kev_count":11,"has_kev":17},"15",1,{"version":26,"cve_count":24,"kev_count":11,"has_kev":17},"15.1","Simatic Wincc Runtime by Siemens is a technology product with 5 tracked versions and 13 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[29,30,31,32,33],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},{"version":19,"cve_count":16,"kev_count":11,"has_kev":17},{"version":21,"cve_count":11,"kev_count":11,"has_kev":17},{"version":23,"cve_count":24,"kev_count":11,"has_kev":17},{"version":26,"cve_count":24,"kev_count":11,"has_kev":17},[35,43,50,58,65,70,77,82,87,92],{"cveId":36,"description":37,"publishedDate":38,"cvssScore":39,"cvssVersion":40,"severity":41,"isKev":4,"epssScore":42},"CVE-2026-111497","A buffer overflow vulnerability in the Brotli decoder (c\u002Fdec\u002Fdecode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.","2026-10-22",9.2,"v4.0","Critical",0.99987,{"cveId":44,"description":45,"publishedDate":46,"cvssScore":47,"cvssVersion":48,"severity":41,"isKev":17,"epssScore":49},"CVE-2011-3321","Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.","2011-09-16",9.3,"v2",0.0707,{"cveId":51,"description":52,"publishedDate":53,"cvssScore":54,"cvssVersion":55,"severity":56,"isKev":17,"epssScore":57},"CVE-2018-13812","A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003C V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions \u003C V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003C V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003C V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003C V15 Update 4), SIMATIC HMI Classic Devices (TP\u002FMP\u002FOP\u002FMP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.","2018-12-13",7.5,"v3.0","High",0.03572,{"cveId":59,"description":60,"publishedDate":61,"cvssScore":62,"cvssVersion":63,"severity":41,"isKev":17,"epssScore":64},"CVE-2019-6572","A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003C V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions \u003C V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003C V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003C V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003C V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003C V15.1 Update 1), SIMATIC HMI Classic Devices (TP\u002FMP\u002FOP\u002FMP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.","2019-05-14",9.1,"v3.1",0.02721,{"cveId":66,"description":67,"publishedDate":68,"cvssScore":54,"cvssVersion":63,"severity":56,"isKev":17,"epssScore":69},"CVE-2021-40142","In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.","2021-08-27",0.02563,{"cveId":71,"description":72,"publishedDate":73,"cvssScore":74,"cvssVersion":55,"severity":75,"isKev":17,"epssScore":76},"CVE-2017-6867","A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface.","2017-05-11",4.9,"Medium",0.01923,{"cveId":78,"description":79,"publishedDate":61,"cvssScore":80,"cvssVersion":63,"severity":75,"isKev":17,"epssScore":81},"CVE-2019-6576","A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003C V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions \u003C V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003C V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003C V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003C V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003C V15.1 Update 1), SIMATIC HMI Classic Devices (TP\u002FMP\u002FOP\u002FMP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.",6.5,0.01783,{"cveId":83,"description":84,"publishedDate":53,"cvssScore":85,"cvssVersion":55,"severity":56,"isKev":17,"epssScore":86},"CVE-2018-13814","A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003C V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions \u003C V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V14), SIMATIC WinCC Runtime Advanced (All versions \u003C V14), SIMATIC WinCC Runtime Professional (All versions \u003C V14), SIMATIC WinCC (TIA Portal) (All versions \u003C V14), SIMATIC HMI Classic Devices (TP\u002FMP\u002FOP\u002FMP Mobile Panel) (All versions). The integrated web server (port 80\u002Ftcp and port 443\u002Ftcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",8.8,0.01684,{"cveId":88,"description":89,"publishedDate":53,"cvssScore":90,"cvssVersion":55,"severity":56,"isKev":17,"epssScore":91},"CVE-2018-13813","A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003C V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions \u003C V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003C V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003C V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003C V15 Update 4), SIMATIC HMI Classic Devices (TP\u002FMP\u002FOP\u002FMP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",8.1,0.01681,{"cveId":93,"description":94,"publishedDate":95,"cvssScore":96,"cvssVersion":55,"severity":56,"isKev":17,"epssScore":97},"CVE-2019-10935","A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003C V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003C V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003C V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003C V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003C V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003C V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003C V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003C V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003C V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003C V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.","2019-07-11",7.2,0.01274,[99],{"cveId":36,"description":37,"publishedDate":38,"cvssScore":39,"severity":41,"isKev":4,"epssScore":42,"cisaVulnName":100,"cisaDateAdded":101,"cisaShortDescription":102,"cisaRequiredAction":103},"Google Brotli Unchecked Return Value Vulnerability","2026-10-27","Google Brotli contains an unchecked return value vulnerability that allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.","Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.",{"title":105,"metaDescription":106,"keywords":107,"structuredData":108},"Simatic Wincc Runtime by Siemens - Security Vulnerabilities & Analysis | EdgeProtect","Comprehensive security analysis for Simatic Wincc Runtime by Siemens covering 5 versions with 13 tracked vulnerabilities including 1 critical and 0 high-severity issues. Real-time threat intelligence, CVE tracking, and security recommendations.","Simatic Wincc Runtime vulnerabilities, Simatic Wincc Runtime security, Simatic Wincc Runtime CVE, Siemens Simatic Wincc Runtime, Simatic Wincc Runtime threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":109,"@type":110,"name":111,"description":106,"url":112,"manufacturer":113,"applicationCategory":117,"softwareVersion":118,"mainEntity":119},"https:\u002F\u002Fschema.org","SoftwareApplication","Simatic Wincc Runtime","https:\u002F\u002Fedgeprotect.io\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsimatic_wincc_runtime",{"@type":114,"name":115,"url":116},"Organization","Siemens","https:\u002F\u002Fedgeprotect.io\u002Fvendors\u002Fsiemens","Security Software","5 versions tracked",{"@type":120,"name":121,"description":122,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Simatic Wincc Runtime Security Vulnerabilities","Security vulnerabilities affecting Simatic Wincc Runtime by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":124,"apiVersion":125},"2026-11-25T11:49:57.498Z","3.0",[127,130,133,135,137],{"product":128,"cves":129},"simatic_wincc_runtime_advanced",12,{"product":131,"cves":132},"simatic_wincc_runtime_professional",9,{"product":134,"cves":24},"simatic_wincc_runtime_comfort",{"product":136,"cves":24},"simatic_wincc_runtime_hsp_comfort",{"product":138,"cves":24},"simatic_wincc_runtime_mobile",{"rows":140,"total":24,"capped":17,"failed":11},[141],{"cveId":36,"name":100,"severity":41,"cvss":39,"added":101,"epss":42,"published":142,"ranges":143,"checked":4,"hits":144,"covers":17},"2026-10-22T14:17:37.19",[],[]]