[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fiYphMZyt5cmxOuYJhb_F3L6jTxmxjJ2aSYlTnfKX100":3,"g5a-risk:CVE-2024-29119":105},{"success":4,"data":5,"meta":102},true,{"cveId":6,"title":7,"description":8,"shortDescription":9,"publishedDate":10,"lastModified":11,"cvssScore":12,"cvssVector":13,"cvssMetrics":14,"epssScore":38,"epssPercentile":28,"epssTimeSeries":39,"severity":41,"affectedProducts":42,"affectedProductsCount":48,"references":49,"referencesCount":48,"weaknesses":55,"weaknessesCount":48,"isActivelyExploited":64,"cisaInfo":28,"otxData":28,"relatedBlogPosts":65,"seoMetadata":66,"configurations":91,"relatedVendorCves":100,"notableEvents":101},"CVE-2024-29119","What is CVE-2024-29119?","A vulnerability has been identified in Spectrum Power 7 (All versions \u003C V24Q3). The affected product contains several root-owned SUID binaries that could allow an authenticated local attacker to escalate privileges.","A vulnerability has been identified in Spectrum Power 7 (All versions \u003C V24Q3). The affected product contains several root-owned SUID binaries that could all...","2024-11-12T13:15:07.263","2026-06-17T07:22:27.2",8.5,"CVSS:4.0\u002FAV:L\u002FAC:L\u002FAT:N\u002FPR:L\u002FUI:N\u002FVC:H\u002FVI:H\u002FVA:H\u002FSC:N\u002FSI:N\u002FSA:N\u002FE:X\u002FCR:X\u002FIR:X\u002FAR:X\u002FMAV:X\u002FMAC:X\u002FMAT:X\u002FMPR:X\u002FMUI:X\u002FMVC:X\u002FMVI:X\u002FMVA:X\u002FMSC:X\u002FMSI:X\u002FMSA:X\u002FS:X\u002FAU:X\u002FR:X\u002FV:X\u002FRE:X\u002FU:X",{"CVSSMetricV31":15,"CVSSMetricV30":31,"CVSSMetricV2":32,"CVSSMetricV40":33},[16],{"Source":17,"Type":18,"CVSSData":19,"ExploitabilityScore":29,"ImpactScore":30},"productcert@siemens.com","Secondary",{"Version":20,"VectorString":21,"AttackVector":22,"AttackComplexity":23,"PrivilegesRequired":23,"UserInteraction":24,"Scope":25,"ConfidentialityImpact":26,"IntegrityImpact":26,"AvailabilityImpact":26,"BaseScore":27,"BaseSeverity":26,"ExploitCodeMaturity":28,"RemediationLevel":28,"ReportConfidence":28,"TemporalScore":28,"TemporalSeverity":28,"ConfidentialityRequirement":28,"IntegrityRequirement":28,"AvailabilityRequirement":28,"ModifiedAttackVector":28,"ModifiedAttackComplexity":28,"ModifiedPrivilegesRequired":28,"ModifiedUserInteraction":28,"ModifiedScope":28,"ModifiedConfidentialityImpact":28,"ModifiedIntegrityImpact":28,"ModifiedAvailabilityImpact":28,"EnvironmentalScore":28,"EnvironmentalSeverity":28},"3.1","CVSS:3.1\u002FAV:L\u002FAC:L\u002FPR:L\u002FUI:N\u002FS:U\u002FC:H\u002FI:H\u002FA:H","LOCAL","LOW","NONE","UNCHANGED","HIGH",7.8,null,1.8,5.9,[],[],[34],{"Source":17,"Type":18,"CVSSData":35},{"Version":36,"VectorString":13,"BaseScore":12,"BaseSeverity":26,"AttackVector":22,"AttackComplexity":23,"AttackRequirements":24,"PrivilegesRequired":23,"UserInteraction":24,"VulnConfidentialityImpact":26,"VulnIntegrityImpact":26,"VulnAvailabilityImpact":26,"SubConfidentialityImpact":24,"SubIntegrityImpact":24,"SubAvailabilityImpact":24,"ExploitMaturity":37,"ConfidentialityRequirement":37,"IntegrityRequirement":37,"AvailabilityRequirement":37,"ModifiedAttackVector":37,"ModifiedAttackComplexity":37,"ModifiedAttackRequirements":37,"ModifiedPrivilegesRequired":37,"ModifiedUserInteraction":37,"ModifiedVulnConfidentialityImpact":37,"ModifiedVulnIntegrityImpact":37,"ModifiedVulnAvailabilityImpact":37,"ModifiedSubConfidentialityImpact":37,"ModifiedSubIntegrityImpact":37,"ModifiedSubAvailabilityImpact":37,"Safety":37,"Automatable":37,"Recovery":37,"ValueDensity":37,"VulnerabilityResponseEffort":37,"ProviderUrgency":37},"4.0","NOT_DEFINED",0.00224,[40,40,40,40,40,38,38],0.00142,"High",[43],{"vendor":44,"product":45,"version":46,"criteria":47,"vulnerable":4},"siemens","spectrum_power_7","*","cpe:2.3:a:siemens:spectrum_power_7:*:*:*:*:*:*:*:*",1,[50],{"url":51,"source":52,"tags":53},"https:\u002F\u002Fcert-portal.siemens.com\u002Fproductcert\u002Fhtml\u002Fssa-616032.html","Siemens",[54],"Vendor Advisory",[56],{"id":57,"name":58,"description":59,"extendedDescription":60,"status":61,"abstraction":62,"structure":63},"CWE-266","Incorrect Privilege Assignment","A product incorrectly assigns a privilege to a particular actor, creating an unintended sphere of control for that actor.","","Draft","Base","Simple",false,[],{"title":67,"metaDescription":68,"keywords":69,"canonicalUrl":70,"structuredData":71},"What is CVE-2024-29119? Vulnerability Analysis | Security Advisory | EdgeProtect","Comprehensive analysis of CVE-2024-29119, a high severity cyber security vulnerability from 2024. A vulnerability has been identified in Spectrum Power 7 (Al...","CVE-2024-29119, CVE-2024-29119 vulnerability, CVE-2024-29119 security, high severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research, vulnerability assessment, cyber threats, 2024, CVSS score, exploit, patch, remediation, siemens security, spectrum_power_7 vulnerability","\u002Fwhat-is\u002Fcve-2024-29119",{"@context":72,"@type":73,"headline":67,"description":68,"datePublished":10,"dateModified":11,"author":74,"publisher":78,"about":82,"mainEntityOfPage":86,"articleSection":89,"keywords":90},"https:\u002F\u002Fschema.org","TechArticle",{"@type":75,"name":76,"url":77},"Organization","EdgeProtect","https:\u002F\u002Fedgeprotect.io",{"@type":75,"name":76,"url":77,"logo":79},{"@type":80,"url":81},"ImageObject","https:\u002F\u002Fedgeprotect.io\u002Fimg\u002Flogos\u002Fedgeprotect-logo-512.png",{"@type":83,"name":6,"description":84,"additionalType":85},"Thing","Cybersecurity Vulnerability","https:\u002F\u002Fschema.org\u002FSoftwareBug",{"@type":87,"@id":88},"WebPage","https:\u002F\u002Fedgeprotect.io\u002Fwhat-is\u002Fcve-2024-29119","Cybersecurity","CVE-2024-29119, CVE-2024-29119 vulnerability, CVE-2024-29119 security, high severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research",[92],{"Operator":28,"Negate":28,"Nodes":93},[94],{"Operator":95,"Negate":64,"CPEMatch":96},"OR",[97],{"Vulnerable":4,"Criteria":47,"MatchCriteriaID":98,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":99,"VersionEndIncluding":28},"60335833-4E79-43C9-B629-1FD9D4D675DA","24q3",[],[],{"lastModified":11,"cacheTime":103,"version":104},1795785733658,"2.0",{"score":106,"band":107,"action":108,"scoredAt":109},47,"Medium","Plan remediation","2026-11-27T07:08:35.25992+00:00"]